TMR 48 X

KEY FEATURES

  • Multi-function or mono-function
  • Multi-range from 0.02 s to 300 h
  • Multi-voltage 12 to 240 V\⎓ / 24 to 240 V ∿
  • Time setting displayed on dial
  • 2 changeover relays 5 A / 250 V∿
  • Display of power and output states by 2 LEDs
  • Housing 48 x 48 mm
FunctionsRelay outputsMax. breaking currentSupply voltageConnectionCode
A1, A2, H1, H2, Q1, Q2, D-Di2 changeover or 1 timed and 1 instantaneous5 A / 250 V∿12 →240 V⎓ 24 →240 V∿Plug-in 8 way88886116

Specifications


Supply voltage Un 12 →240 V⎓ 24 →240 V ∿
Operating range ± 10 % DC supply - 15 % / + 10 % AC supply
Frequency 50 / 60 Hz
Power consumption 4.8 VA / 230 V∿ 2.5 VA / 110 V∿ 1.1 VA / 24 V∿ 0.5 W / 24 V⎓ 0.8 W / 12 V⎓
Timing ranges (14 available options) 0,02 →1,2 s 0,05 →3 s 0,2 →12 s 0,5 →30 s 2 →120 s 5 →300 s 0,2 →12 min. 0,5 →30 min. 2 →120 min. 5 →300 min. 0,2 →12 h 0,5 →30 h 2 →120 h 5 →300 h
Repetition accuracy ± 0.5 % of full scale at 25 °C (typical with constant parameters)
Temperature drift according to CEI/EN 61812 ± 0.05 % of full scale
Display precision ± 5 % of full scale at 25 °C
Minimum pulse duration START 25 ms
Minimum pulse duration GATE 60 ms
Minimum pulse duration RESET 60 ms
Retard à la disponibilité par coupure de tension (START strappé) 50 ms

Nominal rating 2 x 5 A
Nominal insulation voltage 250 V∿
Rated power (resistive load) 2000 VA
Minimum current 10 mA
Electrical life at I max. 250 V ∿ resistive (number of operations) 105
Mechanical life (operations) 30 x 106

Display of output state by 2 LEDs Green : power ON flashing during timing Yellow : ON output ON OFF output OFF
Operating temperature range (°C) -20 →+55
Storage temperature range (°C) -40 →+70
Breakdown voltage 2 KV
Protection class (IEC 60529) - Panel-mounted IP 50
Protection class (IEC EN/60529) - Casing IP 40
Housing material self-extinguishing
Weight (g) 140

Technical sketches

TMR 48 U / A / X / L

TMR 48 U / A / X / L

35 mm DIN rail base with clips 79 237 739

35 mm DIN rail base with clips 79 237 739

Panel cut-out

Panel cut-out

TMR 48 X

TMR 48 X

Function A1 Delay on energisation

Function A1

Delay on energisation

Function A2 Delay on energisation

Function A2

Delay on energisation

Function H1 Timing on energisation

Function H1

Timing on energisation

Function H2 Timing on energisation

Function H2

Timing on energisation

Function Q1 Star-delta

Function Q1

Star-delta

Function Q2 Star-delta 2

Function Q2

Star-delta  2

Function D-Di Cyclic timing : symetric recycler

Function D-Di

Cyclic timing : symetric recycler