EIT

KEY FEATURES

  • Relay output 5 A - 250 V AC - 1 N/O contact
  • Multivoltage power supply : 100 to 230 V AC 50-60 Hz
  • 24 V AC / DC
Measurement rangeSupply voltageCode
10 →100 A : avec transformateur d'intensité24 VDC84871040 Obsolete
10 →100 A : avec transformateur d'intensité24 VAC84871041 Obsolete
10 →100 A : avec transformateur d'intensité48 VAC84871042 Obsolete
10 →100 A : avec transformateur d'intensité120 VAC84871043 Obsolete
10 →100 A : avec transformateur d'intensité230 VAC84871044 Obsolete

Specifications


Type External current transformer
Polarity with ⎓ voltage Yes
∿ supply voltage frequency 50 / 60 Hz
Galvanic isolation of power supply/measurement DC : no galvanic isolation. In this case, the product power supply and measuring circuit power supply must be electrically isolated AC : galvanic isolation by transformer
Measurement range 10 →100 A E1-M
Input resistance 20 Ω
Permanent overload at 25 °C 130 A
Maximum voltage Network 277 V / 480 V∿

Supply voltage Un 24 VDC / 24 VAC / 48 VAC / 120 VAC / 220 VAC
Voltage supply tolerance -15 % / +15 % limited to -15 % / +10 % if products are mounted without space between them
Operating range 0.85 →1.15 Un
Power consumption at Un 3 VA AC 1 W DC
Immunity from micro power cuts 10 ms

Frequency of measured signal 40 →500 Hz
Threshold adjustment 10 →100 % of the measurement range
Adjustable hysteresis 5 →50 % of the displayed threshold
Display precision ± 10 %
Repetition accuracy with constant parameters ± 0.1 %
Measuring error with voltage drift ± 0,1 % (± 10 % Un)
Measuring error with temperature drift ± 0,02 %

Delays on power up (Ti) 0.1 s →20 s ± 10 %
Delay on thresold crossing Tt 0.1 s →3 s ± 10 %
Repetition accuracy with constant parameters ± 0.1 %
Reset time 500 ms
Delay on pick-up 500 ms

Type of output 1 changeover AgNi, 8A AC max
Type of contacts No cadmium
Maximum breaking voltage 250 V ∿/⎓
Max. breaking current 8 A∿ max.
Min. breaking current 100  mA ∿/⎓
Electrical life (number of operations) AC 12 : 2000 VA - 105 AC 15 : Cos φ = 0,3 - 6 000 DC 13 : L/R = 300 ms - 6 000
Breaking capacity (V resistive) 2000 VA ∿
Maximum rate 360 operations/hour at full load
Operating categories acc. to IEC/EN 60947-5-1 AC12, AC15, DC13
Mechanical life (operations) 5 x 106

Insulation coordination (IEC/EN 60664-1) Overvoltage category III : degree of pollution 2
Rated impulse withstand voltage (IEC/EN 60664-1) 4 KV (1,2 / 50 μs)
Dielectric strength (IEC/EN 60664-1) 2,5 KV ∿ 50  Hz 1 min.
Insulation resistance (IEC/EN 60664-1) > 100 MΩ / 500 V⎓

Display power supply Green LED
Display relay Yellow LED
Casing 22,5 mm
Mounting On 35 mm symmetrical DIN rail, IEC/EN 60715
Mounting position All positions
Material : enclosure plastic type VO to UL94 standard Enclosure plastic type VO to UL94 standard
Protection (IEC/EN 60529) Terminal block : IP 20 Casing : IP 50
Weight 140 g
Connecting capacity IEC/EN 60947-1 Rigid  : 1 x 42 - 2 x 2.52 mm2 1 x 11 AWG - 2 x 14 AWG Flexible with ferrules  : 1 x 2.52 - 2 x 1.52 mm2 1 x 14 AWG - 2 x 16 AWG
Max. tightening torques IEC/EN 60947-1 0,6 mN / 5,3 Lbf.In
Operating temperature IEC/EN 60068-2 -20 →+50
Storage temperature IEC/EN 60068-2 -30 →+70
Humidity IEC/EN 60068-2-30 93 % RH max. without condensation
Vibrations according to IEC/EN60068-2-6 10 →55  Hz, A = 0,35 mm

Product standard IEC/EN 60255-1
Electromagnetic compatibility (EMC) IEC/EN 61000-6-1, IEC/EN 61000-6-1, IEC/EN 61000-6-3, IEC/EN 61000-6-4
Certifications UL, CSA
Marking CE (DBT) 2006/95/EC - EMC 2004/108/EC
Conformity with environmental directives RoHS

Technical sketches

AC/DC control with memory

AC/DC control with memory
Legend
1-
Threshold
2-
Hysteresis
3-
UPPER function
4-
UNDER function
5-
Unit power-up
6-
Controlled current
When the value of the controlled current, either AC or DC, reaches the threshold displayed on the front face, the output relay changes state at the end of time delay T1. It returns instantly to the initial state when the current drops below the hysteresis threshold, or when the power supply is disconnected. The output relay changes state at the end of time delay T1 and remains latched in this position. To reset the memory function the auxiliary supply must be disconnected. The time delay on energisation T2 prevents current peaks due to motor starting. The delay on upward crossing of threshold T1 provides immunity to transients and other interference, thereby preventing spurious triggering of the output relay. The time delay on energisation T2 prevents the occurrence of current troughs. The delay on downward crossing of threshold T1 provides immunity to random dips, thereby preventing spurious triggering of the output relay.  : In underload function, the absolute value of the hysteresis cannot be greater than the measurement range maximum.

AC/DC control without memory

AC/DC control without memory
Legend
1-
Threshold
2-
Hysteresis
3-
UPPER function
4-
UNDER function
5-
Unit power-up
6-
Controlled current

EIL / EIH / EIT

EIL / EIH / EIT

EIT

EIT
Legend
A1 - A2 : Supply voltage-
PH 84871034

Share