CTR48E Green backlit

KEY FEATURES

  • Counter, Preselection chronometer
  • Maximum input frequency 5 k  Hz
  • Simple parameter setting, configuration using text menus
  • Easy modification of presets
  • Multiplication factor
  • 3 A changeover relay
  • Backlit LCD display (green)  : 6 digits, height 9 mm
  • IP 65 sealed panel
  • Option of locking the keypad, completely or partially (preset, programming)
  • Accessories for 72 x 72 or 55 x 55 cut-out, DIN rail adaptor
FunctionsPresetVoltagesOutputCode
Counter, Preselection chronometer110 →30 V⎓1 relay87629111
Counter, Preselection chronometer1115 V∿1 relay87629113
Counter, Preselection chronometer1230 V∿1 relay87629114
Counter, Preselection chronometer210 →30 V⎓1 changeover relay, 1 NO relay87629121
Counter, Preselection chronometer2115 V∿1 changeover relay, 1 NO relay87629123
Counter, Preselection chronometer2230 V∿1 changeover relay, 1 NO relay87629124

Specifications


Supply 11 →30 V⎓ / 115 V ∿ / 230 V∿
Relative humidity (no condensation) EN 60068-2-30 40/93 % RLF
Altitude 0 < 2000 m
Certifications CE
Vibration resistance in 3 axes 10-55 Hz/1 min/XYZ EN 60068-2-6 : 30 min. in each direction
Connection by screw terminals Débrochable
Protection Conforming to standard EN 60529 IP65 for panel/IP20 for connections
Front panel watertight seal
Temperature limits use (°C) -10 →+50
Temperature limits stored (°C) -25 →+75
Weight (g) 150 ⎓ version 250 ∿ version

Reset to zero or to preset On panel : if not locked during programming Electrical : automatic, voltage or solid state (NPN or PNP depending on programming)
Minimum pulse time Impulse counter : < 15 ms Chronometer : 500 μs
Option to protect against reset from front panel
Scale factor (each input pulse is multiplied by this figure) 00,0001 →99,9999
Decimal point selectable for ease of reading 0 0,0 0,00 0,000 0,0000 0,00000
Sensor supply version ∿ -40/+15 % 50 mA 230 V∿ -40/+15 % 40 mA 115 V∿
Programming and current value backed up via EEPROM memory • Service life 10 years

Functions Preselection counter, Chronometer
Number of presets 1 or 2
Display LCD with green backlighting
Height digits (mm) LCD 9
Display details - 999 999 →999 999

Inputs 2 counter inputs 1 reset input, 1 locking input
Input modes Dir : Directional AS : up/dn PP : phase
Input type Voltage or solid state
High level 3,5 →30 V⎓
Low level 0 →2 V⎓

Changeover relay
NO contact Depending on version
Maximum current 3 A
Minimum current 30 mA
Maximum voltage 30 V⎓ / 250 V∿
Min. voltage 5 V∿/⎓
Response time < 10 ms
Mechanical life (operations) 20 x 106
Number of operations 1 x 105
Output modes : maintained or pulsed 0.01 →99.99 s

Technical sketches

Legend
1-
10.5 max

Panel cut-out

Panel cut-out

26546842 - Adaptor for 72 x 72 mm cut-out

26546842 - Adaptor for 72 x 72 mm cut-out

26546846 - Adaptor for 55 x 55 mm cut-out

26546846 - Adaptor for 55 x 55 mm cut-out

26546841 - DIN rail adaptor

26546841 - DIN rail adaptor

87629111

87629111
Legend
1-
Sensor voltage supply (* UB interconnected)
2-
GND (0 V⎓)
3-
INP A (signal A input)
4-
INP B (signal B input)
5-
Reset (Reset input)
6-
Lock (locking switch input)
7-
11-12-13 : Output 1
8-
14-15 : Supply
9-
Power supply - GND

87629113 / 114

87629113 / 114
Legend
1-
Sensor voltage supply
2-
GND (0 V⎓)
3-
INP A (signal A input)
4-
INP B (signal B input)
5-
Reset (Reset input)
6-
Lock (locking switch input)
7-
11-12-13 : Output 1
8-
14-15 : Supply

87629121

87629121
Legend
1-
Sensor voltage supply (* UB interconnected)
2-
GND (0 V⎓)
3-
INP A (signal A input)
4-
INP B (signal B input)
5-
Reset (Reset input)
6-
Lock (locking switch input)
7-
9-10 : Output 1
8-
11-12-13 : Output 2
9-
14-15 : Supply
10-
Power supply - GND

87629123 / 124

87629123 / 124
Legend
1-
Sensor voltage supply
2-
GND (0 V⎓)
3-
INP A (signal A input)
4-
INP B (signal B input)
5-
Reset (Reset input)
6-
Lock (locking switch input)
7-
9-10 : Output 1
8-
11-12-13 : Output 2
9-
14-15 : Supply

Counter : dir

Counter : dir
Inp A : counter input Inp B : count direction rS0 : Display 0 →Preset rSP2 : Display Preset →0

Counter : AS

Counter : AS
Inp A : Add. counter input 1 Inp B : Sub. counter input 2 rS0 : Display 0 →Preset rSP2 : Display Preset →0

Counter : PP

Counter : PP
A 90° B Inp A : counter input counting on an edge Inp B : reversal of direction rS0 : Display 0 →Preset rSP2 : Display Preset →0

Chronometer : Start tcCAb

Chronometer : Start tcCAb
Inp A : On Inp B : Off Add : Display 0 →Preset Sub : Display Preset →0

Chronometer : Start tcCbb

Chronometer : Start tcCbb
Inp A : No function Inp B : On/Off RS0/RSP2 Add : Display 0 →Preset Sub : Display Preset →0

Chronometer : Start FrErun

Chronometer : Start FrErun
InpA : Gate Time measurement via InpA InpB : No function

Output operation 1 : rS0

Output operation 1 : rS0

Output operation 1 : rSA0

Output operation 1 : rSA0

Output operation 1 : rSP2

Output operation 1 : rSP2

Output operation 1 : rSAP2

Output operation 1 : rSAP2

Output operation 2 : rS0

Output operation 2 : rS0

Output operation 2 : rSA0

Output operation 2 : rSA0

Output operation 2 : rSP2

Output operation 2 : rSP2

Output operation 2 : rSAP2

Output operation 2 : rSAP2
PH 87621112

Programming diagram

Programming diagram

Share
Share
elementum felis elit. diam Donec Praesent